From field projection to intensity
In a linearly polarized wave, the electric field oscillates along a fixed direction perpendicular to propagation. An ideal linear polarizer transmits the component parallel to its axis. If δ is the angle between the incident field and that axis, the transmitted amplitude is E times the cosine of δ. Average intensity is proportional to amplitude squared, giving Malus's law:
A transmission axis is an undirected line: θ and θ + 180° describe the same polarizer. Angles are measured counterclockwise from the horizontal, viewed from the detector toward the source. All axes must use that same convention. Ideal transmission is complete for parallel axes and zero for perpendicular axes.
Source and transmission through each stage
Let I₀ be the incident intensity, N the number of polarizers and θₖ the axis of filter k. Unpolarized light has no preferred polarization direction: the average of cos² δ is 1/2. Its first filter therefore transmits half the average intensity. For linearly polarized light with axis α, the first factor depends on θ₁ − α.
After each filter, transmitted light with positive intensity is polarized along its axis. For k ≥ 2, the local factor is qₖ = cos²(θₖ − θₖ₋₁). Intensity and cumulative transmittance follow:
q compares a stage with its immediate input; T compares it with the source. Both are fractions between 0 and 1, or percentages when multiplied by 100. Transmittance depends on the axes and polarization state and remains defined even when I₀ is zero.
Intensity balance and extinction
For a fixed setup, every factor qₖ lies between 0 and 1: intensity never increases as light passes through a filter. If Dₖ is the intensity not transmitted at that stage, the balance is:
“Not transmitted” does not necessarily mean absorbed. In a real device, that light may be absorbed, reflected or directed into another branch. Ideal extinction means zero output intensity; there is then no outgoing field to which a polarization axis can be assigned.
Three filters and projection order
Crossed filters at 0° and 90° ideally extinguish the light. Inserting a filter at 45° between them transmits 1/8 of an unpolarized source's intensity. Inserting it after the crossed pair does not recover the light: changing the order changes the result.
Inserting a filter changes the field orientation reaching the next one, so the comparison involves two different setups. For unpolarized input and N filters with axes evenly spaced between 0° and 90°, total transmittance is:
As N increases, each change in orientation becomes smaller and the transmittance of this sequence approaches 1/2. The first polarizer still rejects half the unpolarized intensity.
Required incident intensity
For a nonnegative target intensity I⋆ and a setup with positive transmittance TN, the required incident intensity is:
If TN = 0, no finite incident intensity can produce a positive output. If the target is also zero, any nonnegative incident intensity satisfies the condition. By contrast, when TN is positive, zero output requires I₀ = 0. Switching off the source and crossing two axes can yield the same final intensity but describe different physical situations.
Possible orientations and angular sweep
For fixed positive incident intensity, finding an angle θ means solving T(θ)=I0I⋆. If only one projection changes, the response has the form C cos²(θ − a), where C contains the factors independent of θ and a is the fixed comparison axis.
If two projections change, a and b are the fixed axes immediately before and after the filter; a can be the linearly polarized source axis when the first polarizer is rotated. In this case:
For a nonconstant response, there can be up to four distinct solutions in [0°, 180°). With unpolarized input and axes 0°–θ–90°, an output of 6.25 % of I₀ corresponds to 22.5°, 67.5°, 112.5° and 157.5°. The 12.5 % maximum occurs at 45° and 135°; a higher output is impossible with that incident intensity.
If transmittance is independent of θ, the target admits either every orientation or none. Examples include a single polarizer receiving unpolarized light and extinction caused by other fixed axes. If I₀ = 0, every angle gives zero output.
The sweep expresses percentages relative to I₀; its peaks are not normalized to 100 %. Near an extremum, small intensity changes can produce large changes in the inferred angle. Decimal precision in a calculation and uncertainty in a measurement are different concepts.
Physical quantity and scope of the approximation
The intensity considered is average irradiance: power per unit area perpendicular to the beam, measured in W/m². The conversion is 1 mW/cm² = 10 W/m². Irradiance is neither total power nor illuminance in lux; converting it to power requires the illuminated area and its intensity distribution.
The description follows one transmitted branch of a coaxial beam through ideal linear polarizers, with either fully linearly polarized or unpolarized input. Angles change in the transverse plane: rotating a transmission axis is different from changing the beam's angle of incidence on the filter.
The parallel component is assumed to be transmitted perfectly and the perpendicular component completely rejected. Leakage, retardance and interference between multiple reflections are excluded. The ideal law is independent of wavelength, although a real polarizer's transmittance and extinction can vary with it.
Circularly polarized light also transmits half its intensity through an ideal linear polarizer, but this does not make it unpolarized. Circular, elliptical and partially polarized states require a description beyond a single axis.